Technical Information

The all in one standard and high temperature solutions with materials for surface preparation, reinforcement and topcoat consists of:




  Standard Temperature High Temperature
Repair classes 1, 2 and 3 1, 2 and 3
Defect types Type A (none through wall defects)
Type B (through wall defects)
Type A (none through wall defects)
Type B (through wall defects)
Pipe substrates Carbon steel, stainless steel,
duplex, super duplex
Carbon steel
Piping components Straight, bend, reducer, T-piece, flange Straight, bend, reducer, T-piece, flange
Maximum pressure According to specific repair design According to specific repair design
Temperature range type A
Temperature range type B
-50 °C to 80 °C
-50 °C to 70 °C
-50 °C to 130 °C
-50 °C to 120 °C
Repair method Grit blasting / wire brushing
Full wrap / patch lay-up
No peel-ply / with peel-ply
Grit blasting / wire brushing
Full wrap / patch lay-up
With peel-ply LOCTITE PC 5090
Post cure 3 hours at 90 °C
Chemicals (type B defect)* Water
Acids
Alkaline
Hydrocarbons (liquids & gases)
Water
Acids
Alkaline
Hydrocarbons (liquids & gases)
Approvals DNVGL & Lloyds Register DNVGL certified according to ISO 24817 and ASME PCC-2

TÜV Rheinland
DNVGL certified according to ISO 24817


Contact


Contact us now!
Videos & Literature